- #Turn on disk uid on an hp smart array controller driver
- #Turn on disk uid on an hp smart array controller software
- #Turn on disk uid on an hp smart array controller series
This should output a list of all the drives in the system as shown below. So after digging through the help documentation, I found the necessary HPSSACLI command to enable the drive’s UID.įirst, to get a list of all the physical drives in an ESXi host, SSH the host and run this command: /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 physicaldrive all show

Unfortunately, while ILO is great at identifying the defective drive, it has no ability to enable the UID on the drive, and given that this unit is at a remote site, we had no way of knowing in advanced if the fault light was actually turn on for this drive before the HPE field engineering arrived to swap the drive. Status Messages SCREENSHOT 9) Exit the controller to reboot the machine.Įxit Smart Storage Administrator SCREENSHOT 10) Confirm by clicking on “OK” to exit the configuration utility Smart Storage Administrator.This morning we needed to replace a hard drive in a HPE Proliant running VMware ESXi at a remote site that had a PFA on it.
View all status messages SCREENSHOT 8) The warning reports the controller needs a reboot to enable HBA mode.

Click on “View all status messages” to view the message. Scroll down for more details.Įnable HBA Mode – details screen 1 SCREENSHOT 4) Here you can see the details of “Encryption settings” and part of “Controller Configuration Summery”.Įnable HBA Mode – details screen 2 SCREENSHOT 5) Here you can see the details of “Controller Configuration Summery”, “Port Settings”, “Controller Status”.Įnable HBA Mode – details screen 3 SCREENSHOT 6) Here you can see the details of “Port Settings”, “Controller Status”, “Temperature Sensors” and “Storage Enclosures”.Įnable HBA Mode – details screen 4 SCREENSHOT 7) You can see there is a warning message. Here you can see the details of “Controller Hardware Information” and “Controller Power Settings”. So you must reboot before the controller gets in HBA mode. SCREENSHOT 2) Confirm by clicking on “OK” if you want to enable HBA Mode of the controller.Īll disks with Smart Array configuration will be disabled and won’t be usable.Įnable HBA Mode – confirmation SCREENSHOT 3) “The controller has been set to enable HBA mode after reboot.” The following screenshots start with a controller in hardware mode in (HPE terms – Smart Array Mode), then enable the HBA mode, the OS will see the disks as JBOD and then again enable the hardware mode (Smart Array Mode): SCREENSHOT 1) Click on the controller “Smart Array P440” on the left and then “Enable HBA Mode” to enable JBOD mode.
#Turn on disk uid on an hp smart array controller driver
#Turn on disk uid on an hp smart array controller software
When using software solution like software RAID or LVM (and the controller is in JBOD) you can move the disks with no problem to other hardware without the hardware controller. When you create virtual drives in hardware mode, you must use only this type of proprietary controller or some compatible of the same company.
#Turn on disk uid on an hp smart array controller series
As a continuation of our series about HPE Smart Array P440 controller here how you can enable HBA mode of your controller.